使用401脫氧柱時,以下幾點需要特別注意:
?
老化處理:新柱或長期未用的柱在使用前需進行老化。先在常溫下通載氣約10分鐘排除柱內空氣,再以程序升溫至最高使用溫度(280°C)老化1-2小時。老化時切勿連接檢測器,以免污染。
載氣要求:載氣中的微量氧也可能損壞固定相,因此建議使用高純載氣,并確保其中氧氣含量不超過1 ppm。必要時可為載氣加裝脫氧管。
安裝方向:安裝時注意色譜柱的進口和出口方向(通常產品有標識,如牌號面向操作者時左側為進口)。
安全操作:拆卸色譜柱前,務必先將柱溫降至室溫,然后再關閉載氣。
?
?
選擇401脫氧柱時,需要考慮以下幾個因素:
儀器匹配:確認脫氧柱的接口規格(如1/8英寸、1/4英寸)與你的氣相色譜儀(如安捷倫、島津、賽默飛等品牌多種型號均適用28)的進樣口和檢測器接口是否匹配。
應用需求:根據你的分析樣品(如工業氫、高純氧)和分析目的(脫氧或氧氬分離)選擇合適的柱長、內徑和填料粒度。
材質選擇:常見為不銹鋼材質,也可選擇玻璃柱管。
訂購說明:如需特殊的柱端堵頭(如不銹鋼過濾網)或采用
?
名稱:脫氧柱
型號:401
規格:3m*3mm,0.4-0.8mm
zui高使用溫度:280°C
應用:工業氫中氧氬的分離
?
浩瀚色譜(山東)應用技術開發有限公司,研制生產的《401脫氧填充色譜柱應用在島津2010?》,測定工業氫中氧氬,脫除干凈,在安捷倫,島津,賽默飛,瓦里安,布魯克,PE上結果滿意。
?
適用于:
安捷倫490在線/便攜,4890,5890,6890,7820,7890,8860,8890
島津GC-14C,GC-2010,GC-2014,GC-2030
賽默飛1310,1300,1610,1600
瓦里安3800系列
布魯克PE580,590,680,690
磐諾A90,福立GC9790,華愛,天瑞,天美,GC7900,川儀,北分瑞利,東西電子,魯南瑞虹,捷島/科曉
?
?





When using a 401 deoxygenation column, the following points need to be paid special attention to:
Aging treatment: New or unused columns need to be aged before use. First, let the air flow through the column at room temperature for about 10 minutes to remove the air inside. Then, use a programmed heating method to reach the maximum operating temperature (280 ° C) and age for 1-2 hours. Do not connect the detector during aging to avoid contamination.
Carrier gas requirements: Trace amounts of oxygen in the carrier gas may also damage the stationary phase, so it is recommended to use high-purity carrier gas and ensure that the oxygen content does not exceed 1 ppm. If necessary, a deoxygenation tube can be installed for the carrier gas.
Installation direction: Pay attention to the inlet and outlet directions of the chromatography column during installation (usually the product is labeled, such as the left side indicating the inlet when the brand is facing the operator).
Safe operation: Before disassembling the chromatography column, make sure to lower the column temperature to room temperature before turning off the carrier gas.
When choosing a 401 deoxygenation column, the following factors need to be considered:
Instrument matching: Confirm whether the interface specifications of the deoxygenation column (such as 1/8 inch, 1/4 inch) match the injection port and detector interface of your gas chromatograph (applicable to multiple models of brands such as Agilent, Shimadzu, Thermo Fisher, etc.).
Application requirements: Choose the appropriate column length, inner diameter, and packing particle size based on your analysis sample (such as industrial hydrogen, high-purity oxygen) and analysis purpose (deoxygenation or oxygen argon separation).
Material selection: Stainless steel is commonly used, but glass column tubes can also be chosen.
Ordering instructions: If you need special column end plugs (such as stainless steel filter screens) or
Name: Deoxygenation Column
Model: 401
Specification: 3m * 3mm, 0.4-0.8mm
Maximum operating temperature: 280 ° C
Application: Separation of oxygen and argon in industrial hydrogen
Haohan Chromatography (Shandong) Application Technology Development Co., Ltd. has developed and produced the "401 Deoxygenation Filled Chromatography Column Application in Shimadzu 2010", which measures oxygen and argon in industrial hydrogen, removes them completely, and achieves satisfactory results on Agilent, Shimadzu, Thermo Fisher, Varian, Brooke, and PE.
Suitable for:
Agilent 490 online/portable, 48905890689088608890
Shimadzu GC-14C, GC-2010, GC-2014, GC-2030
Thermo Fisher Scientific 1310130016101600
Varian 3800 Series
Brooke PE580590680690
Panno A90, Fuli GC9790, Huaai, Tianrui, Tianmei, GC7900, Chuanyi, Beifen Ruili, Dongxi Electronics, Lunan Ruihong, Jiedao/Kexiao
滕州市浩瀚色譜儀器技術服務有限公司
電話:0632-5667636
傳真:0632-5667636
手機:15562228838,13963221227
地址:山東滕州市平行路(商務部和技術部)
郵箱:[email protected]
QQ:1404939462
聯系人:王經理
網址:www.shoxu.cn